Click here to go to UPSCALE home page.
Click here to go to I Year Lab home page.
You can jump directly to a section of this specification sheet by selecting an item below and clicking the left button.
SHUNT
Manufacturer: Philips
Model: PM9244
Cost: $87 (1982)
Description
A device that allows the measurement of currents
up to 31.6 A with a 100 mV meter
Specifications
Current ranges | 10 A and 31.6 A DC or AC 1 kHz |
Output voltage | Max. 100 mV or max. 31.6 mV in both ranges. Adaptable by switch 100 mV/31.6 mV |
Accuracy | Range 100 mV±1% |
| Range 31.6 mV±2% |
Dissipation | 3.15 Watt |
Voltage with respect to earth | <= 400 V AC |
Dimensions | 140 x 65 x 55 mm |
Click here to go to the top of this page.
keywords: voltage measurement device, electrical measurement device.
Document created circa 1982. Original author: Unknown.
Last updated 08/01/96. Revised by Jaime Espinoza and David Harrison.